Review Lesson Plans and Track Progress
Free PDF 2025 EXIN CDCP–Efficient Reliable Test Review
You will remain updated with the CDCP practice test style, evaluate and improve your concepts. Users of the software can improve what they lack before EXIN CDCP final exam. Practicing for the CDCP Practice Test, again and again, can be nerve-wracking, so in this situation Exams. EXIN offer an easy-to-use CDCP PDF questions file.
Do not hesitate to seek our extraordinary EXIN CDCP practice material to make a name in the field of Technology. PassTestking has designed the EXIN CDCP product in three formats. You will find their specifications below to comprehend them better.
>> Reliable CDCP Test Review <<
Trustworthy EXIN CDCP Exam Content, CDCP Latest Test Practice
It is a challenging exam and not a traditional exam. But complete EXIN CDCP exam preparation can enable you to crack the EXIN CDCP exam easily. For the quick and complete Certified Data Centre Professional (CDCP) (CDCP) exam preparation you can trust CDCP Exam Practice test questions. The EXIN CDCP exam practice test questions have already helped many EXIN CDCP exam candidates in their preparation and success.
EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q59-Q64):
NEW QUESTION # 59
Sprinkler heads used in computer rooms activate at what temperature?
Answer: D
Explanation:
Sprinkler heads used in computer rooms activate at 57 °C (135 °F), which is the standard temperature rating for ordinary sprinklers. This is the temperature at which the heat-sensitive element of the sprinkler head, such as a glass bulb or a fusible link, breaks or melts, allowing water to flow from the sprinkler. Sprinkler heads are designed to activate only when exposed to a fire, not to ambient temperature fluctuations. Therefore, sprinkler heads should be installed at a sufficient distance from the heat sources, such as servers, racks, or ducts, to avoid accidental activation. Sprinkler heads should also be selected and installed in accordance with the relevant standards and codes, such as NFPA 13 and NFPA 75.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Sprinkler Systems in Data Centers3, page 1, section 1 4:
Data Center Fire Protection5, page 1, section 2 6: Data Center Sprinkler System Design7, page 1, section 1
NEW QUESTION # 60
What is the most preferred unit of measure for cooling capacity?
Answer: C
Explanation:
Cooling capacity is the measure of a cooling system's ability to remove heat from a space. The most preferred unit of measure for cooling capacity is watt (W), which is the SI unit for power. Watt is defined as the amount of energy transferred or converted per unit time. One watt is equal to one joule of energy per second. Using watt as the unit of measure for cooling capacity allows for easy comparison and calculation of the cooling performance and efficiency of different cooling systems.
Other units of measure for cooling capacity are ton, BTU, and horsepower, but they are less common and less convenient than watt. Ton is a unit of measure that describes how much water at freezing temperature can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. BTU (British Thermal Unit) is a unit of measure that describes the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit, equivalent to 0.293 W. Horsepower is a unit of measure that describes the rate at which work is done, equivalent to 746 W.
References:
*Data Centre Professional (CDCP®) Reference Materials, page 8, section 2.1.1
*Data Centre Professional (CDCP®) Preparation Guide, page 11, section 2.1.1
*Cooling capacity - Wikipedia
*Air Conditioner BTU Calculator
*Air conditioning 101: Basics, working principle and sizing ... - GlobalSpec
*How is cooling capacity measured? - Sage-Advices
*Everything You Need to Know About Cooling Capacity
NEW QUESTION # 61
What should be considered when implementing hot- or cold-aisle containment in an existing computer room?
Answer: B
Explanation:
Hot- or cold-aisle containment is a strategy to improve the cooling efficiency and reduce the energy consumption of data centers by isolating the hot exhaust air from the cold supply air. However, implementing this strategy in an existing computer room may create potential issues with the existing fire suppression system(s), such as:
*The containment barriers may interfere with the distribution and activation of the fire suppression agents, such as water, gas, or aerosol, and reduce their effectiveness in extinguishing a fire.
*The containment barriers may create pockets of high temperature and pressure that could damage the equipment or the containment structure itself in the event of a fire.
*The containment barriers may obstruct the access and visibility of the fire detection and alarm devices, such as smoke detectors, heat sensors, or manual call points, and delay the response time of the fire suppression system(s).
*The containment barriers may violate the local fire codes and regulations that specify the minimum clearance and ventilation requirements for the data center.
Therefore, when implementing hot- or cold-aisle containment in an existing computer room, it is important to consider the impact on the existing fire suppression system(s) and take appropriate measures to ensure the safety and compliance of the data center, such as:
*Consulting with the fire authorities and the fire suppression system vendor to assess the compatibility and suitability of the containment solution with the existing fire suppression system(s).
*Modifying or upgrading the existing fire suppression system(s) to accommodate the containment solution, such as relocating or adding fire suppression devices, adjusting the discharge rate and pressure, or installing a secondary fire suppression system within the contained area.
*Installing fire-rated containment barriers that can withstand high temperatures and resist the spread of fire and smoke, and that have self-closing or automatic release mechanisms in case of a fire.
*Installing fire detection and alarm devices within the contained area and ensuring their proper integration and communication with the existing fire suppression system(s).
*Conducting regular testing and maintenance of the fire suppression system(s) and the containment solution to ensure their functionality and reliability.
References: EPI Data Centre Framework, Module 4: Fire Protection, page 10-11. EPI Data Centre Professional (CDCP®) Reference Materials, page 66-67. 1, 2, 3.
NEW QUESTION # 62
Cost of Downtime can be classified as.
Answer: A
Explanation:
Cost of downtime is the total amount of money lost due to a data centre outage or disruption. It can be classified into two categories: direct and indirect. Direct costs are the immediate and measurable expenses incurred during or after an outage, such as lost revenue, lost productivity, recovery costs, compensation costs, penalties, etc. Indirect costs are the long-term and intangible impacts of an outage, such as reputation damage, customer dissatisfaction, loss of market share, legal liabilities, etc. Both direct and indirect costs can vary depending on the type, duration, and severity of the outage, as well as the industry, size, and location of the data centre.
References:
*EPI Data Centre Training Framework1
*EPI Data Centre Competence Framework2
*Understanding the Cost of Data Center Downtime3
*Uptime Institute's 2022 Outage Analysis Finds Downtime Costs and Consequences Worsening
*[INFOGRAPHIC] The Cost of Downtime: 21 Stats You Need to Know
NEW QUESTION # 63
Where should exit/emergency signs be located?
Answer: B
Explanation:
According to the EPI Data Centre Operations Standard (DCOS), exit/emergency signs should be located at every escape door and pathways leading to doors (arrows) to ensure a safe and quick evacuation in case of an emergency1. This is also consistent with the best practices for data centre emergency preparedness and response, which recommend having a clear and visible signage system for emergency exits23.
References: 1: EPI Data Centre Operations Standard (DCOS), Version 2.0, Section 5.4.2.1, Page 42 2: How to Prepare and Respond to Data Center Emergencies, White Paper 217, Schneider Electric, Page 4 3: How to Properly Manage Data Center Emergencies, IT Business Edge, Slide 2
NEW QUESTION # 64
......
In order to save a lot of unnecessary trouble to users, we have completed our CDCP Learning Materials research and development of online learning platform, users do not need to download and install, only need your digital devices have a browser, can be done online operation of the CDCP study materials. This kind of learning method is very convenient for the user, especially in the time of our fast pace to get EXIN certification. In addition, our test data is completely free of user's computer memory, will only consume a small amount of running memory when the user is using our product.
Trustworthy CDCP Exam Content: https://www.passtestking.com/EXIN/CDCP-practice-exam-dumps.html
EXIN Reliable CDCP Test Review We provide 100% guaranteed success with the use of our products, EXIN Reliable CDCP Test Review If you miss one important chance you may need to strive five years more, precise accurate and abridged in the form of a few Trustworthy CDCP Exam Content - Certified Data Centre Professional (CDCP) questions and answers, Features of our web-based certification for Certified Data Centre Professional (CDCP) (CDCP) practice test and the desktop simulation software for EXIN CDCP exam questions are similar.
Book author Sharon Steuer miss the most when she's creating art using traditional media, By comparison, CDCP vce exam is easier for you to remember the CDCP Exam Questions And Answers of dumps.
Pass Guaranteed CDCP - Certified Data Centre Professional (CDCP) Newest Reliable Test Review
We provide 100% guaranteed success with the use of our products, If you miss CDCP one important chance you may need to strive five years more, precise accurate and abridged in the form of a few Certified Data Centre Professional (CDCP) questions and answers.
Features of our web-based certification for Certified Data Centre Professional (CDCP) (CDCP) practice test and the desktop simulation software for EXIN CDCP exam questions are similar.
All customer information to purchase our CDCP guide torrent is confidential to outsides.